Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)
HomeHome > Products > MIM Medical Instrument > Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)
Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)

Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)

Product Description The LongmedTM Endo Fascial Closure System is designed to minimize complications and costs associated
Basic Info.
Model NO. UP-1231
Function Shrink Vagina, Treat Vaginal Problems
Transport Package OEM
Specification FCS-15, 13, 10, 8, 5
Trademark UPLINE
Origin China
HS Code 901839000
Production Capacity 5000PCS/Week
Product Description

Product Description

The LongmedTM Endo Fascial Closure System

is designed to minimize complications

and costs associated with post-operative

port-site herniation by providing safety,

uniform closure.


Advantage

Unique safety fascial closure device

More comfortable to use

Meet clinical needs

1.Blunt TIP

Reduces potential of injury to internal structures upon insertion.

2.TRIANGULAR PROTECTION

Provides safety target point for suture passer.

Avoid injury to surrounding structures or organs when sewing.

Captures suture ends.

3.CENTER SHAFT AND APPROXIMATION WINGS

Provides stability.

Indicates abdominal wall.

Unassisted approximation&removal of suture strand.

4.GUIDE CHANNELS

Designed to minimize risk of needlestick injury.

Defined path for delivery of suture directly to the depth control pads.

5.LOCKING DEVICE

Locking state more tightly, effectively prevent sutures from escaping.

6.SUTURE PASSERT

Anti-slip point design, easy to operate with gloves.


Specification

Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)



Operation Instruction
STEP 1-PACKAGE CONTENTS Remove the longmedTM Device and Suture Passer from package. Set the device aside and pick up only the suture passer with the black triangle on the thumb handle facing up. Slide off the protectivesheath from suture passer with the distal tip pointed away from your body. STEP 2-LOADING THE SUTURE PASSER Make a 3 cm loop with size 0 or 1 suture and guide suture passer tip through loop about halfway down the shaft. Now with a slight downward pressure of the suture loop on the metal shaft, slide the suture towards the distal end until it falls into the notch portion. Immediately pull back towards the thumb handle to lock suture into place. For now you can set this aside until Step 4. STEP 3-DEPLOYING WINGS Insert the Longmed TM Device into defect allowing for ample space between peritoneal membrane and wings. Secure device with index finger and thumb on finger grips and draw back on ring handle deploying wings and immediately turn handle to the left to lock. STEP 4-DELIVERING SUTURE It is important to keep the device stable during each pass. Grasp the device firmly with index finger and thumb on the finger pads while resting your palm on the abdomen for added stability. Insert the preloaded suture passer down one of the two guide channels through the silicone pad .. Emmediately turn handle to the right to unlock,ensurepass moves forward consistently andsmoothly through layer and finally reach thesafety target point . STEP 5- CLEARING THE GUIDE CHANNEL Gently remove the outer suture loop from the guide channel slits. Lay the loop on the abdomen freefrom obstruction. During removal of the device, allow the loop to slide down into the defect . STEP 6- APPROXIMATE THE WINGS
Turn the ring handle to the right to the unlock position. With the device stable, press down on thering handle to bring the wings with captured suture together for easy removal . STEP 7- REMOVAL OF DEVICE Remove the entire device from the defect slowly until you are able to free the suture ends from the silicone pads by hand. Once removed, pull up on the two suture ends and allow outer loop to fall down into the defect . STEP 8- CLOSURE OF DEFECT Use standard tie down techniques to obtain desired closure. Palpate defect to ensure full closurecompleting the process .
Factory Show

Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)


Shipping Show

Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)


Team Support

Medical Instruments of Laparoscopic Instrument (MIM Atraumatic Grasper)


FAQ
1. Q: Are you a factory or trading company?
A: We are an industrial and trade one
2. Q: How many workers in factory?
A: About 100
3. Q: What is your main products?
A: Our main products are disposable feeding bag, urine bag, disposable paper drape, surgical drape, underpad, non-woven gowns, face masks, non-woven sheets, shoe covers, gauze swab, cotton swab, suture line, suction catheter, plastic cap...
4
Q: How to get a sample?
A: Some models would be free if we have stocks Charged, depend on which style, color and logo printing you required.
5. Q: What's your advantage?
A: (1) Competitive price (2) High quality (3) One stop purchasing (4) Fast response and professional suggestion on all inquiries (5) Quality guarantee
6. Q: What is your Minimum quantity ?
A: Based on the style, color and other details you ordered
7. Q: How long to deliver the products?
A: The exact delivery date need to according to your style and quantity. Usually within 30 work days after receive full payment down payment .if your amount more than $5000,you can pay 30% first,and pay for 70%before shipment.If you choose the items which we have stock ,we can deliver in 3 days.
8. Q: How to contact with you?
A: You can send us an inquiry by email for detailed contact information.